Sign In to gain access to subscriptions and/or personal tools.
|
 |
Screening Library Evolution through Automation of Solution Preparation
U. Schopfer*,
F. Höhn,
M. Hueber,
M. Girod,
C. Engeloch,
M. Popov,
I. Muckenschnabel
Novartis Pharma AG
* To whom correspondence should be addressed. E-mail: ulrich.schopfer{at}novartis.com.
 |
Abstract |
|---|
The quality of the compound library is a critical success factor in every high-throughput screening campaign. Screening solutions have to be prepared with a high level of process control to ensure the correct identity and initial concentration of each compound. However, even under optimized storage conditions, a certain level of degradation in solution cannot be avoided. Therefore, regular quality control and eventual removal of solutions from the screening deck is necessary. Because solution preparation, especially the weighing of compounds, is a tedious and often manual task, a regular resolubilization of compounds is difficult to achieve. By complete automation of the solution preparation, the authors have laid the foundation for a life cycle management of screening solutions. They demonstrate how a combination of quality and process control leads to a continuous improvement of the screening library. In presenting an automation concept, they show how a series of innovative process optimizations led to a high-performance system that achieves full industrialization of solution preparation. (Journal of Biomolecular Screening XXXX:xx-xx)
First published on May 16, 2007, doi:10.1177/1087057107301939
Journal of Biomolecular Screening 2007;12:724.
A more recent version of this article appeared on August 1, 2007

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
W. P. Janzen and I. G. Popa-Burke
Review: Advances in Improving the Quality and Flexibility of Compound Management
J Biomol Screen,
June 1, 2009;
14(5):
444 - 451.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
R. MacArthur, W. Leister, H. Veith, P. Shinn, N. Southall, C. P. Austin, J. Inglese, and D. S. Auld
Monitoring Compound Integrity With Cytochrome P450 Assays and qHTS
J Biomol Screen,
June 1, 2009;
14(5):
538 - 546.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
C. Engeloch, U. Schopfer, I. Muckenschnabel, F. Le Goff, H. Mees, K. Boesch, and M. Popov
Stability of Screening Compounds in Wet DMSO
J Biomol Screen,
December 1, 2008;
13(10):
999 - 1006.
[Abstract]