Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here for more information

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Journal of Biomolecular Screening
This Article
Right arrow Full Text (OnlineFirst PDF)
Right arrow All Versions of this Article:
1087057107299527v1
12/3/396    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Kool, J.
Right arrow Articles by Vermeulen, N. P. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kool, J.
Right arrow Articles by Vermeulen, N. P. E.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Article

Online Biochemical Detection of Glutathione-S-Transferase P1-Specific Inhibitors in Complex Mixtures

Jeroen Kool1, Mark Eggink1, Huub Van Rossum1, Sebastiaan M. Van Liempd1, Danny A. Van Elswijk2, Hubertus Irth2, Jan N. M. Commandeur1, John H. N. Meerman1, Nico P. E. Vermeulen1*

1 LACDR-Division of Molecular Toxicology, Department of Pharmacochemistry, Vrije Universiteit, Amsterdam, the Netherlands.
2 Kiadis B.V., Groningen, the Netherlands.

* To whom correspondence should be addressed. E-mail: npe.vermeulen{at}few.vu.nl.


   Abstract

A high-resolution screening (HRS) technology is described, which couples 2 parallel enzyme affinity detection (EAD) systems for substrates and inhibitors of rat cytosolic glutathione-S-transferases (cGSTs) and purified human GST P1 to gradient reversed-phase high-performance liquid chromatography (HPLC). The cGSTs and GST P1 EAD systems were optimized and validated first in flow injection analysis (FIA) mode, and optimized values were subsequently used for HPLC mode. The IC50 values of 8 ligands thus obtained online agreed well with the IC50 values obtained with microplate reader-based assays. For ethacrynic acid, an IC50 value of 1.8 ± 0.4 µM was obtained with the cGSTs EAD system in FIA mode and 0.8 ± 0.6 µM in HPLC mode. For ethacrynic acid with the GST P1 EAD system, IC50 values of 6.0 ± 2.9 and 3.6 ± 2.8 µM were obtained in FIA and HPLC modes, respectively. An HRS GST EAD system, consisting of both the cGSTs and the GST P1 EAD system in HPLC mode in parallel, was able to separate complex mixtures of compounds and to determine online their individual affinity for cGSTs and GST P1. Finally, a small library of GST inhibitors, synthesized by reaction of several electrophiles with glutathione (GSH), was successfully screened with the newly developed parallel HRS GST EAD system. It is concluded that the present online gradient HPLC-based HRS screening technology offers new perspectives for sensitive and simultaneous screening of general cGSTs and specific GST P1 inhibitors in mixtures.

Key Words: glutathione S-tranferases (GSTs), glutathione S-tranferase PI (GST P1), enzyme affinity detection (EAD), high-resolution screening (HRS), online

First published on March 22, 2007, doi:10.1177/1087057107299527

Journal of Biomolecular Screening 2007;12:396.

A more recent version of this article appeared on April 1, 2007


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
J Biomol ScreenHome page
J. Kool, A. Van Marle, S. Hulscher, M. Selman, D. J. Van Iperen, K. Van Altena, M. Gillard, R. A. Bakker, H. Irth, R. Leurs, et al.
A Flow-Through Fluorescence Polarization Detection System for Measuring GPCR-Mediated Modulation of cAMP Production
J Biomol Screen, December 1, 2007; 12(8): 1074 - 1083.
[Abstract] [PDF]