Sign In to gain access to subscriptions and/or personal tools.
|
 |
Investigation of 3 Industry-Wide Applied Storage Conditions for Compound Libraries
Pierre E. Ilouga1,
Dirk Winkler1*,
Christian Kirchhoff1,
Bernd Schierholz1,
Julian Wölcke2
1 Evotec AG, Hamburg, Germany.
2 Evotec AG, Hamburg, Germany.; Novartis Institutes for Biomedical Research, Basel, Switzerland.
* To whom correspondence should be addressed. E-mail: dirk.winkler{at}evotec.com.
 |
Abstract |
|---|
The appropriate storage conditions for a compound file are a crucial factor for the success of drug discovery projects. In this study, 778 highly diverse compounds dissolved in 100% DMSO were stored under 3 industry-wide accepted storage conditions, and the compound integrity was monitored for a period of 6 months. The storage conditions selected were (1) under argon at +15 °C, (2) under argon at -20 °C, and (3) under ambient atmosphere at -20 °C. Each sample was assessed every 4 weeks by liquid chromatography coupled to mass spectrometry (LC/MS). Based on the resulting experimental data, a statistical projection of compound integrity over a period of 4 years for each of the 3 storage conditions was generated applying a linear mixed-effects model. A moderate loss of compound integrity of 12% was calculated for storage at -20 °C under argon, a loss of 21% for storage at -20 °C under ambient atmosphere, and a strong decrease of 58% for storage at +15 °C under argon over this period. The initial purity of the compounds does also influence the rate of compound degradation. Compounds with an initial purity of 50% to 75% degraded faster than compounds with an initial purity of more than 75%. The results of the study enable the prediction of the point in time, when the purity of a compound population falls below a predefined threshold that would trigger the resolubilization or retirement of the compound population represented by the analyzed samples.
Key Words:
drug discovery, compound integrity, compound storage, liquid chromatography coupled to mass spectrometry (LC/MS), high-throughput screening (HTS), linear mixed-effects model
First published on November 12, 2006, doi:10.1177/1087057106295507
Journal of Biomolecular Screening 2007;12:21.
A more recent version of this article appeared on February 1, 2007

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
Z. Blaxill, S. Holland-Crimmin, and R. Lifely
Stability Through the Ages: The GSK Experience
J Biomol Screen,
June 1, 2009;
14(5):
547 - 556.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
W. P. Janzen and I. G. Popa-Burke
Review: Advances in Improving the Quality and Flexibility of Compound Management
J Biomol Screen,
June 1, 2009;
14(5):
444 - 451.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
R. MacArthur, W. Leister, H. Veith, P. Shinn, N. Southall, C. P. Austin, J. Inglese, and D. S. Auld
Monitoring Compound Integrity With Cytochrome P450 Assays and qHTS
J Biomol Screen,
June 1, 2009;
14(5):
538 - 546.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
S. L. Matson, M. Chatterjee, D. A. Stock, J. E. Leet, E. A. Dumas, C. D. Ferrante, W. E. Monahan, L. S. Cook, J. Watson, N. J. Cloutier, et al.
Best Practices in Compound Management for Preserving Compound Integrity and Accurately Providing Samples for Assays
J Biomol Screen,
June 1, 2009;
14(5):
476 - 484.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
C. Engeloch, U. Schopfer, I. Muckenschnabel, F. Le Goff, H. Mees, K. Boesch, and M. Popov
Stability of Screening Compounds in Wet DMSO
J Biomol Screen,
December 1, 2008;
13(10):
999 - 1006.
[Abstract]
[PDF]
|
 |
|
|
|