Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here for more information

Sign In to gain access to subscriptions and/or personal tools.
Journal of Biomolecular Screening
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
1087057109341768v1
14/8/1008    most recent
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Shapiro, A. B.
Right arrow Articles by Keating, T. A.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shapiro, A. B.
Right arrow Articles by Keating, T. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Correction for Interference by Test Samples in High-Throughput Assays

Adam B. Shapiro

AstraZeneca R&D Boston, Waltham, Massachusetts, adam.shapiro{at}astrazeneca.com

Grant K. Walkup

AstraZeneca R&D Boston, Waltham, Massachusetts

Thomas A. Keating

AstraZeneca R&D Boston, Waltham, Massachusetts

In high-throughput biochemical assays performed in multiwell plates, the effect of test samples on the activity of the biochemical system is usually measured by optical means such as absorbance, fluorescence, luminescence, or scintillation counting. The test sample often causes detection interference when it remains in the well during the measurement. Interference may be due to light absorption, fluorescence quenching, sample fluorescence, chemical interaction of the sample with a detection reagent, or depression of the meniscus. A simple method is described that corrects for such interference well by well. The interference is measured in a separate artifact assay plate. An appropriate arithmetic correction is then applied to the measurement in the corresponding well of the activity assay plate. The correction procedure can be used for single-point screening or potency measurements on serial dilutions of test samples.

Key Words: high-throughput screening • interference • correction • fluorescence resonance energy transfer • scintillation proximity assay

This version was published on September 1, 2009

Journal of Biomolecular Screening, Vol. 14, No. 8, 1008-1016 (2009)
DOI: 10.1177/1087057109341768


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?