Journal of Biomolecular Screening

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
1087057107312628v1
13/2/159    most recent
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhijin Wu,
Right arrow Articles by Yunxia Sui,
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhijin Wu,
Right arrow Articles by Yunxia Sui,
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
This version was published on February 1, 2008
Journal of Biomolecular Screening, Vol. 13, No. 2, 159-167 (2008)
DOI: 10.1177/1087057107312628

Quantitative Assessment of Hit Detection and Confirmation in Single and Duplicate High-Throughput Screenings

Zhijin Wu

Center for Statistical Sciences, zhijin_wu{at}brown.edu, Department of Community Health, Brown University, Providence, Rhode Island

Dongmei Liu

Department of Epidemiology and Population Health, London School of Hygiene and Tropical Medicine, United Kingdom

Yunxia Sui

Department of Community Health, Brown University, Providence, Rhode Island

The process of identifying active targets (hits) in high-throughput screening (HTS) usually involves 2 steps: first, removing or adjusting for systematic variation in the measurement process so that extreme values represent strong biological activity instead of systematic biases such as plate effect or edge effect and, second, choosing a meaningful cutoff on the calculated statistic to declare positive compounds. Both false-positive and false-negative errors are inevitable in this process. Common control or estimation of error rates is often based on an assumption of normal distribution of the noise. The error rates in hit detection, especially false-negative rates, are hard to verify because in most assays, only compounds selected in primary screening are followed up in confirmation experiments. In this article, the authors take advantage of a quantitative HTS experiment in which all compounds are tested 42 times over a wide range of 14 concentrations so true positives can be found through a dose-response curve. Using the activity status defined by dose curve, the authors analyzed the effect of various data-processing procedures on the sensitivity and specificity of hit detection, the control of error rate, and hit confirmation. A new summary score is proposed and demonstrated to perform well in hit detection and useful in confirmation rate estimation. In general, adjusting for positional effects is beneficial, but a robust test can prevent overadjustment. Error rates estimated based on normal assumption do not agree with actual error rates, for the tails of noise distribution deviate from normal distribution. However, false discovery rate based on empirically estimated null distribution is very close to observed false discovery proportion. (Journal of Biomolecular Screening 2008:159-167)

Key Words: high-throughput screening • hit detection • error rate • hit confirmation • false discovery rate


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?